Collect


Blood, Red

Preferred Draw Volume

10 mL whole blood (4 mL serum)

Minimum Draw Volume

4 mL whole blood (2 mL serum)

Unacceptable Conditions

Plasma, serum separator tube, non-fasting or lipemic samples.

Patient Preparation


Fast 12 hours prior to collection.

Collection Comments

This test requires 4 mL of serum. Collect two, 6 mL Red Top tubes. Allow red tube to sit for 30 minutes to form clot. Spin for 10 minutes at 1100-1300 g in a swing bucket unit or 15 minutes in a fixed angle to separate cells from serum. Remember to properly label tube with patient name, DOB, test and collect date. Separate from cells within 8 hours. Transfer 4 mL serum (minimum 2 mL serum) to a properly labeled aliquot tube and refrigerate.

http://ltd.aruplab.com/Tests/Pub/2013716

Storage/Transport Temperature

Refrigerated serum

Stability (from collection to initiation)

Ambient: 24 hours; Refrigerated: 2 weeks; Frozen: Unacceptable

Special Handling

LAB: Remove from Cells within 2 hours

Ordering Recommendations

Use in appropriate high-risk patients (eg, type 2 diabetes mellitus) in whom LDL particle number is being used to guide therapy. Not recommended for cardiovascular disease risk assessment in most individuals; preferred test is Lipid Panel http://ltd.aruplab.com/Tests/Pub/2013716

Performed

Sunday-Saturday

Methodology

Quantitative Nuclear Magnetic Resonance Spectroscopy/ Quantitative Enzymatic/ Detergent Solubilization

Reported

4-7 days

Performing Lab

Send Outs

Referral Lab

ARUP Laboratories

Synonyms

  • 10419
  • LIPOFIT
  • NMR Lipoprofile
  • vldl
  • ARUP 2013716
  • Lipid Profile, NMR
  • Expanded (NMR LipoProfile Test)

Reference Interval

By Report

Clinical Interpretation

CPT Codes

83704, 80061

LOINC Codes

  NAME LOINC
Order LipoFit by NMR 59062-0

Test Code (Outreach Synonym)

10419

Catalog Code

6542506471
Collection

Collect


Blood, Red

Preferred Draw Volume

10 mL whole blood (4 mL serum)

Minimum Draw Volume

4 mL whole blood (2 mL serum)

Unacceptable Conditions

Plasma, serum separator tube, non-fasting or lipemic samples.

Patient Preparation


Fast 12 hours prior to collection.

Collection Comments

This test requires 4 mL of serum. Collect two, 6 mL Red Top tubes. Allow red tube to sit for 30 minutes to form clot. Spin for 10 minutes at 1100-1300 g in a swing bucket unit or 15 minutes in a fixed angle to separate cells from serum. Remember to properly label tube with patient name, DOB, test and collect date. Separate from cells within 8 hours. Transfer 4 mL serum (minimum 2 mL serum) to a properly labeled aliquot tube and refrigerate.

http://ltd.aruplab.com/Tests/Pub/2013716

Storage/Transport Temperature

Refrigerated serum

Stability (from collection to initiation)

Ambient: 24 hours; Refrigerated: 2 weeks; Frozen: Unacceptable

Special Handling

LAB: Remove from Cells within 2 hours
Ordering

Ordering Recommendations

Use in appropriate high-risk patients (eg, type 2 diabetes mellitus) in whom LDL particle number is being used to guide therapy. Not recommended for cardiovascular disease risk assessment in most individuals; preferred test is Lipid Panel http://ltd.aruplab.com/Tests/Pub/2013716

Performed

Sunday-Saturday

Methodology

Quantitative Nuclear Magnetic Resonance Spectroscopy/ Quantitative Enzymatic/ Detergent Solubilization

Reported

4-7 days

Performing Lab

Send Outs

Referral Lab

ARUP Laboratories

Synonyms

  • 10419
  • LIPOFIT
  • NMR Lipoprofile
  • vldl
  • ARUP 2013716
  • Lipid Profile, NMR
  • Expanded (NMR LipoProfile Test)
Result Interpretation

Reference Interval

By Report

Clinical Interpretation

Additional Information

CPT Codes

83704, 80061

LOINC Codes

  NAME LOINC
Order LipoFit by NMR 59062-0

Test Code (Outreach Synonym)

10419

Catalog Code

6542506471