Collect

Collect random urine in sterile container and transfer to the UA preservative (URYEL) container, allowing urine to fill to the fill-line. Container should be filled between the min and max fill-lines. If less than 7.0 mL of urine, submit in container or syringe.

Preferred Container

Preferred:  UA Preservative container (URYEL)
Acceptable:  UA Preservative container (URSPCKL)

Preferred Collection Volume

7.0 - 9.0 mL urine

Specimen Preparation

Invert container 8-10 times to ensure the preservative is well mixed with the urine.

Pediatric Collection

Collect random urine in sterile container and transfer to the UA preservative (URYEL) container, allowing urine to fill to the fill-line. Container should be filled between the min and max fill-lines. If less than 7.0 mL of urine, submit in container or syringe.

Onsite Collection Instructions

Transport at room temperature. Specimen collected in sterile container or syringe should arrive in the lab within one hour of collection (Chandler & Good Samaritan).

Offsite Collection Instructions

Transport at room temperature. Specimen collected in sterile container or syringe should arrive in the lab within one hour of collection.

Stability (from collection to initiation)

In preservative container: room temperature - 72 hours
Not in preservative container: room temperature - 2 hours, refrigerated - 4 hours

Required Testing Volume

7.0 - 9.0 mL urine

Minimum Volume

4.0 mL urine

Storage/Transport Temperature

Transport to lab immediately at room temperature. Specimen collected in sterile container or syringe should arrive in the lab within one hour of collection since only stable at room temperature for 2 hours.

Unacceptable Conditions

Unpreserved specimens exceeding stability or improperly filled preservative containers will be rejected.

Miscellaneous Information

Includes: bilirubin, blood (occult), color, glucose, ketones, leukocytes, nitrite, pH, protein, specific gravity & clarity, and urobilinogen

Performed

24/7

Turn Around Time

Stat: 90 minutes
Routine: 240 minutes

Performing Lab

Chandler Core - Urinalysis, Chandler ED Laboratory (dipstick only) & Good Samaritan Laboratory

Methodology

Dry pad chemistry

Synonyms

  • UAR

Notes

Novus or Advantus for Chemsitries, UF1000 or Manual Microscopic, if reflexed.

Reference Interval

Color: No reference range
Clarity: No reference range
Glucose: Negative (mg/dL)
Protein: Negative (mg/dL)
Bilirubin: Negative
Blood: Negative
Ketones: Negative
Urobilinogen: 0.2 - 1.0 EU/dL
Leukocyte esterase: Negative
Nitrite: Negative
pH:  4.5 - 8
Specific gravity:  1.005 - 1.030 

Reflexed Microscopic:
WBC: 0 - 5/HPF
RBC: 0-3/HPF
Epithelial Cells: 0 - 5/HPF
Hyaline Casts: 0 - 8/LPF
Pathological Cast: 0/LPF
Bacteria: Negative
All other elements: Absent

Interpretive Data

A urine microscopic examination will be reflexed if any of the following urine chemistry conditions are met: trace blood or greater, trace leukocyte esterase or greater, positive nitrite, or protein >= 300.

LOINC

  • 57020-0

Laboratory Department

Urinalysis
Collection

Collect

Collect random urine in sterile container and transfer to the UA preservative (URYEL) container, allowing urine to fill to the fill-line. Container should be filled between the min and max fill-lines. If less than 7.0 mL of urine, submit in container or syringe.

Preferred Container

Preferred:  UA Preservative container (URYEL)
Acceptable:  UA Preservative container (URSPCKL)

Preferred Collection Volume

7.0 - 9.0 mL urine

Specimen Preparation

Invert container 8-10 times to ensure the preservative is well mixed with the urine.

Pediatric Collection

Collect random urine in sterile container and transfer to the UA preservative (URYEL) container, allowing urine to fill to the fill-line. Container should be filled between the min and max fill-lines. If less than 7.0 mL of urine, submit in container or syringe.

Onsite Collection Instructions

Transport at room temperature. Specimen collected in sterile container or syringe should arrive in the lab within one hour of collection (Chandler & Good Samaritan).

Offsite Collection Instructions

Transport at room temperature. Specimen collected in sterile container or syringe should arrive in the lab within one hour of collection.

Stability (from collection to initiation)

In preservative container: room temperature - 72 hours
Not in preservative container: room temperature - 2 hours, refrigerated - 4 hours

Required Testing Volume

7.0 - 9.0 mL urine

Minimum Volume

4.0 mL urine

Storage/Transport Temperature

Transport to lab immediately at room temperature. Specimen collected in sterile container or syringe should arrive in the lab within one hour of collection since only stable at room temperature for 2 hours.

Unacceptable Conditions

Unpreserved specimens exceeding stability or improperly filled preservative containers will be rejected.

Miscellaneous Information

Includes: bilirubin, blood (occult), color, glucose, ketones, leukocytes, nitrite, pH, protein, specific gravity & clarity, and urobilinogen

Performed

24/7
Ordering

Turn Around Time

Stat: 90 minutes
Routine: 240 minutes

Performing Lab

Chandler Core - Urinalysis, Chandler ED Laboratory (dipstick only) & Good Samaritan Laboratory

Methodology

Dry pad chemistry

Synonyms

  • UAR

Notes

Novus or Advantus for Chemsitries, UF1000 or Manual Microscopic, if reflexed.
Result Interpretation

Reference Interval

Color: No reference range
Clarity: No reference range
Glucose: Negative (mg/dL)
Protein: Negative (mg/dL)
Bilirubin: Negative
Blood: Negative
Ketones: Negative
Urobilinogen: 0.2 - 1.0 EU/dL
Leukocyte esterase: Negative
Nitrite: Negative
pH:  4.5 - 8
Specific gravity:  1.005 - 1.030 

Reflexed Microscopic:
WBC: 0 - 5/HPF
RBC: 0-3/HPF
Epithelial Cells: 0 - 5/HPF
Hyaline Casts: 0 - 8/LPF
Pathological Cast: 0/LPF
Bacteria: Negative
All other elements: Absent

Interpretive Data

A urine microscopic examination will be reflexed if any of the following urine chemistry conditions are met: trace blood or greater, trace leukocyte esterase or greater, positive nitrite, or protein >= 300.
Administrative

LOINC

  • 57020-0

Laboratory Department

Urinalysis