Ordering Recommendations

Preferred test to detect herpes simplex virus types 1 and 2 (HSV-1/HSV-2).

Orderable SIM Number(s)

HSV PCR (LAB917)

Synonyms

  • LAB917
  • HSV Types 1 and 2
  • HSV
  • Herpes Simplex Virus, Type 1/2 DNA, Real-Time PCR,
  • Herpes Simplex DNA by PCR

ARUP Test Code

2010095

Collect

Lavender (EDTA), pink (K2EDTA), or serum separator tube. OR CSF, bronchoalveolar lavage (BAL), amniotic fluid, vesicle fluid, ocular fluid, tissue. OR endocervical specimen in ThinPrep Pap Test media.

Specimen Preparation

Separate plasma or serum from cells. Transfer 1 mL plasma, serum, CSF, BAL, amniotic fluid, ocular fluid or ThinPrep specimen to a sterile container. (Min: 0.5 mL)
Tissue: Transfer to a sterile container and freeze immediately.
Vesicle fluid: Transfer to viral transport media (ARUP supply #12884). Available online through eSupply using ARUP Connect(TM)or contact ARUP Client Services at (800) 522-2787.

Storage/Transport Temperature

* Freeze specimen*
Both ARUP viral transport media AND UTM viral transport media can be used.
     
                                     

 

Unacceptable Conditions

Heparinized specimens, tissues in optimal cutting temperature compound.

Stability (from collection to initiation)

Tissue: Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 3 months
All others: Ambient: 8 hours; Refrigerated: 72 hours; Frozen: 3 months

Special Handling Instructions

Do not order this test if there is a Viral Meningoencepahlitis Panel (VMEPRZ) on CSF ordered.  This test is included in that panel.

Remarks

Specimen source required.

Interpretive Data

A negative result does not rule out the presence of PCR inhibitors in the patient specimen or test-specific nucleic acid in concentrations below the level of detection by this test.

This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the U.S. Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

CPT Codes

87529 x2

Billable SIM Number(s)

3008752901

LOINC

  • 31208-2
  • 16130-7
  • 16131-5
Overview

Ordering Recommendations

Preferred test to detect herpes simplex virus types 1 and 2 (HSV-1/HSV-2).

Orderable SIM Number(s)

HSV PCR (LAB917)

Synonyms

  • LAB917
  • HSV Types 1 and 2
  • HSV
  • Herpes Simplex Virus, Type 1/2 DNA, Real-Time PCR,
  • Herpes Simplex DNA by PCR

ARUP Test Code

2010095
Specimen

Collect

Lavender (EDTA), pink (K2EDTA), or serum separator tube. OR CSF, bronchoalveolar lavage (BAL), amniotic fluid, vesicle fluid, ocular fluid, tissue. OR endocervical specimen in ThinPrep Pap Test media.

Specimen Preparation

Separate plasma or serum from cells. Transfer 1 mL plasma, serum, CSF, BAL, amniotic fluid, ocular fluid or ThinPrep specimen to a sterile container. (Min: 0.5 mL)
Tissue: Transfer to a sterile container and freeze immediately.
Vesicle fluid: Transfer to viral transport media (ARUP supply #12884). Available online through eSupply using ARUP Connect(TM)or contact ARUP Client Services at (800) 522-2787.

Storage/Transport Temperature

* Freeze specimen*
Both ARUP viral transport media AND UTM viral transport media can be used.
     
                                     

 

Unacceptable Conditions

Heparinized specimens, tissues in optimal cutting temperature compound.

Stability (from collection to initiation)

Tissue: Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 3 months
All others: Ambient: 8 hours; Refrigerated: 72 hours; Frozen: 3 months

Special Handling Instructions

Do not order this test if there is a Viral Meningoencepahlitis Panel (VMEPRZ) on CSF ordered.  This test is included in that panel.

Remarks

Specimen source required.
Interpretive

Interpretive Data

A negative result does not rule out the presence of PCR inhibitors in the patient specimen or test-specific nucleic acid in concentrations below the level of detection by this test.

This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the U.S. Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

Coding

CPT Codes

87529 x2

Billable SIM Number(s)

3008752901

LOINC

  • 31208-2
  • 16130-7
  • 16131-5