Gross lipemia. Hemolysis can interfere with assay.
Collection Comments
Do not collect in Orange Tube. Allow Gold tube to sit for 30 minutes to form clot. Spin for 10 minutes at 1100-1300 g in a swing bucket unit or 15 minutes in a fixed angle to separate cells from serum. Refrigerate spun tube. Remember to properly label tube with patient name, DOB, test and collect date. If collecting in Red, spin, separate, transfer serum to aliquot tube and refrigerate.
Storage/Transport Temperature
Refrigerated serum
Stability (from collection to initiation)
After separation from cells: Refrigerated: 7 days; Frozen: indefinitely
Ordering Recommendations
The Ribosomal P Ab EIA test uses an enzyme immunoassay test to detect auto-antibodies to ribosomal protein P. These autoantibodies are highly specific (but relatively insensitive) when applied to the diagnosis of systemic lupus erythematosus (SLE). Thistest may be ordered when there is a suspicion of SLE and, if present, this antibody may indicate that the patient with SLE has central nervous system involvement from the disease.
Performed
Monday - Saturday; Days
Methodology
Multiplex Flow Immunoassay
Reported
1-3 days
Performing Lab
Serology
Synonyms
5992
Ribosomal P Prot Ab Ser
Reference Interval
Ab Index < 1.0 - Negative; Ab Index >/= 1.0 - Positive
CPT Codes
83516
LOINC Codes
NAME
LOINC
Order
Ribosomal P Ab EIA
13636-6
Result
Ribosomal P Ab EIA
13636-6
Test Code (Outreach Synonym)
5992
Catalog Code
703788694
Collection
Collect
Blood, Gold
Preferred Draw Volume
2 mL
Minimum Draw Volume
0.8 mL
Other Acceptable Containers
Red
Pediatric Collection
2 microtainers
Unacceptable Conditions
Gross lipemia. Hemolysis can interfere with assay.
Collection Comments
Do not collect in Orange Tube. Allow Gold tube to sit for 30 minutes to form clot. Spin for 10 minutes at 1100-1300 g in a swing bucket unit or 15 minutes in a fixed angle to separate cells from serum. Refrigerate spun tube. Remember to properly label tube with patient name, DOB, test and collect date. If collecting in Red, spin, separate, transfer serum to aliquot tube and refrigerate.
Storage/Transport Temperature
Refrigerated serum
Stability (from collection to initiation)
After separation from cells: Refrigerated: 7 days; Frozen: indefinitely
Ordering
Ordering Recommendations
The Ribosomal P Ab EIA test uses an enzyme immunoassay test to detect auto-antibodies to ribosomal protein P. These autoantibodies are highly specific (but relatively insensitive) when applied to the diagnosis of systemic lupus erythematosus (SLE). Thistest may be ordered when there is a suspicion of SLE and, if present, this antibody may indicate that the patient with SLE has central nervous system involvement from the disease.
Performed
Monday - Saturday; Days
Methodology
Multiplex Flow Immunoassay
Reported
1-3 days
Performing Lab
Serology
Synonyms
5992
Ribosomal P Prot Ab Ser
Result Interpretation
Reference Interval
Ab Index < 1.0 - Negative; Ab Index >/= 1.0 - Positive