Collect

EDTA (purple) tube

Unacceptable Conditions

Hemolyzed,
>24 hours at room temperature

Storage/Transport Temperature

Internal Samples: Transport EDTA tubes to Metabolic lab at room temperature. 

External Samples: WBC pellets from EDTA blood samples should be separated at the source, frozen and shipped on dry ice.



 

Stability (from collection to initiation)

Internal: EDTA tubes can be stored at 4°C for 24 hours prior to arrival in Metabolic lab.

External: WBC pellets stored at -80°C are stable for 3 months.

 

Volume Required

4 mL

Minimum Required

2 mL

Phlebotomy Draw

Yes

Collection Times

On Fridays or the day before a holiday, call the Metabolic lab at 215-590-3394 prior to draw. 

Performing Lab

Metabolic Lab

Performed

Every 2 Weeks

Methodology

UPLC

Reported

14 days

Synonyms

  • Coenzyme Q10
  • Leukocyte Coenzyme Q
  • Leukocyte CoQ10
  • WBC Q10
  • Coenzyme Q

Available STAT

No

Interpretive Data

The levels of coenzyme Q10 in leukocytes correlate with muscle coenzyme Q10 levels, Low levels of Coenzyme Q10 can be seen as a secondary finding in patients with mitochondrial oxidative phosphorylation defects and patients treated with statin therapy. It can also be seen as a primary deficiency in patients with pathogenic variants affecting coenzyme Q10 biosynthesis. Coenzyme Q10 levels are serially tracked in patients on coenzyme Q10 therapy to ensure the levels are normal or high, consistent with therapeutic efficacy. 

Reference Ranges

136 - 247 pmol/mg protein of WBC

CPT Codes

82542

Billing (EAP) Codes

803336

Interpretive Data

The levels of coenzyme Q10 in leukocytes correlate with muscle coenzyme Q10 levels, Low levels of Coenzyme Q10 can be seen as a secondary finding in patients with mitochondrial oxidative phosphorylation defects and patients treated with statin therapy. It can also be seen as a primary deficiency in patients with pathogenic variants affecting coenzyme Q10 biosynthesis. Coenzyme Q10 levels are serially tracked in patients on coenzyme Q10 therapy to ensure the levels are normal or high, consistent with therapeutic efficacy. 
Collection

Collect

EDTA (purple) tube

Unacceptable Conditions

Hemolyzed,
>24 hours at room temperature

Storage/Transport Temperature

Internal Samples: Transport EDTA tubes to Metabolic lab at room temperature. 

External Samples: WBC pellets from EDTA blood samples should be separated at the source, frozen and shipped on dry ice.



 

Stability (from collection to initiation)

Internal: EDTA tubes can be stored at 4°C for 24 hours prior to arrival in Metabolic lab.

External: WBC pellets stored at -80°C are stable for 3 months.

 

Volume Required

4 mL

Minimum Required

2 mL

Phlebotomy Draw

Yes

Collection Times

On Fridays or the day before a holiday, call the Metabolic lab at 215-590-3394 prior to draw. 
Ordering

Performing Lab

Metabolic Lab

Performed

Every 2 Weeks

Methodology

UPLC

Reported

14 days

Synonyms

  • Coenzyme Q10
  • Leukocyte Coenzyme Q
  • Leukocyte CoQ10
  • WBC Q10
  • Coenzyme Q

Available STAT

No
Result Interpretation

Interpretive Data

The levels of coenzyme Q10 in leukocytes correlate with muscle coenzyme Q10 levels, Low levels of Coenzyme Q10 can be seen as a secondary finding in patients with mitochondrial oxidative phosphorylation defects and patients treated with statin therapy. It can also be seen as a primary deficiency in patients with pathogenic variants affecting coenzyme Q10 biosynthesis. Coenzyme Q10 levels are serially tracked in patients on coenzyme Q10 therapy to ensure the levels are normal or high, consistent with therapeutic efficacy. 

Reference Ranges

136 - 247 pmol/mg protein of WBC
Administrative

CPT Codes

82542

Billing (EAP) Codes

803336

Interpretive Data

The levels of coenzyme Q10 in leukocytes correlate with muscle coenzyme Q10 levels, Low levels of Coenzyme Q10 can be seen as a secondary finding in patients with mitochondrial oxidative phosphorylation defects and patients treated with statin therapy. It can also be seen as a primary deficiency in patients with pathogenic variants affecting coenzyme Q10 biosynthesis. Coenzyme Q10 levels are serially tracked in patients on coenzyme Q10 therapy to ensure the levels are normal or high, consistent with therapeutic efficacy.