Ordering Recommendations

Integrated Genetics requires a maternal blood sample to conduct maternal cell contamination testing in conjunction with all prenatal molecular testing. Both amniotic fluid and CVS may have maternal cells present in the sample. These do not usually interfere with the accuracy of chromosome analysis, but are well-recognized as a potential source of error in molecular diagnosis. Integrated Genetics requires a maternal sample in order to provide maximal accuracy in prenatal molecular testing conducted in our laboratory.

Collect

Lavender (EDTA)

Specimen Preparation

10 mL whole blood required

Storage/Transport Temperature

Store and ship ambient.  

Remarks

Genetic consent form from Integrated Genetics required.

Lab Section

Send-out Lab

Methodology

Analysis of short tandem repeat markers by polymerase chain reaction (PCR) and capillary electrophoresis

Reported

11-21 days

Reference Lab Number

528

Performing Laboratory Website (click below)

Notes

Integrated Genetics requires a maternal blood sample to rule out the presence of maternal cells in prenatal samples of uncultured amniotic fluid, CVS, or CVS cultures.

Interpretive Data

By report.

CPT Codes

81265

Order Type (Individual or Group)

I

Result Test ID

MATCR

Reportable?

Y

Result Test Name

MATERNAL CELL CONTAMINATION

Result Type (Individual or Group)

I

Type (Alpha or Numeric)

A

Default Result

See Text

Text

GENETIC CONSENT FORM FROM INTEGRATED GENETICS REQUIRED

CPT Codes

81265

Pricing

Refer to Lab Account Manager. email: labservicesoutreach@urmc.rochester.edu
Specimen Requirements

Ordering Recommendations

Integrated Genetics requires a maternal blood sample to conduct maternal cell contamination testing in conjunction with all prenatal molecular testing. Both amniotic fluid and CVS may have maternal cells present in the sample. These do not usually interfere with the accuracy of chromosome analysis, but are well-recognized as a potential source of error in molecular diagnosis. Integrated Genetics requires a maternal sample in order to provide maximal accuracy in prenatal molecular testing conducted in our laboratory.

Collect

Lavender (EDTA)

Specimen Preparation

10 mL whole blood required

Storage/Transport Temperature

Store and ship ambient.  

Remarks

Genetic consent form from Integrated Genetics required.

Testing

Lab Section

Send-out Lab

Methodology

Analysis of short tandem repeat markers by polymerase chain reaction (PCR) and capillary electrophoresis

Reported

11-21 days

Reference Lab Number

528

Performing Laboratory Website (click below)

Notes

Integrated Genetics requires a maternal blood sample to rule out the presence of maternal cells in prenatal samples of uncultured amniotic fluid, CVS, or CVS cultures.

Result Interpretation

Interpretive Data

By report.

Coding

CPT Codes

81265

URM Labs Internal
Test Build

Order Type (Individual or Group)

I

Result Test ID

MATCR

Reportable?

Y

Result Test Name

MATERNAL CELL CONTAMINATION

Result Type (Individual or Group)

I

Type (Alpha or Numeric)

A

Default Result

See Text

Text

GENETIC CONSENT FORM FROM INTEGRATED GENETICS REQUIRED

CPT Codes

81265

Pricing

Refer to Lab Account Manager. email: labservicesoutreach@urmc.rochester.edu